gpt4 book ai didi

c# - 使用 windbg 调试 .net 应用程序,无法插入断点

转载 作者:太空狗 更新时间:2023-10-29 23:12:37 26 4
gpt4 key购买 nike

我使用 windbg 来调试一个简单的 C# 应用程序,它只包含像这样的空形式:

using System;
using System.Collections.Generic;
using System.ComponentModel;
using System.Data;
using System.Drawing;
using System.Text;
using System.Windows.Forms;

namespace WindowsFormsApp2
{
public partial class Form1 : Form
{
public Form1()
{
InitializeComponent();
}

private void Form1_Load(object sender, EventArgs e)
{

}
}
}

我编译、运行这个应用程序,用 windbg 附加到它,然后在 windbg 中运行:

0:009> .cordll -ve -u -l
Automatically loaded SOS Extension
CLRDLL: Loaded DLL C:\Windows\Microsoft.NET\Framework64\v2.0.50727\mscordacwks.dll
CLR DLL status: Loaded DLL C:\Windows\Microsoft.NET\Framework64\v2.0.50727\mscordacwks.dll

然后我加载 SOS 扩展并验证其已加载:

0:009> .loadby sos mscorwks
0:009> .chain
Extension DLL search Path:
C:\Program Files (x86)\Windows Kits\10\Debuggers\x64\WINXP;C:\Program Files (x86)\Windows Kits\10\Debuggers\x64\winext;C:\Program Files (x86)\Windows Kits\10\Debuggers\x64\winext\arcade;C:\Program Files (x86)\Windows Kits\10\Debuggers\x64\pri;C:\Program Files (x86)\Windows Kits\10\Debuggers\x64;C:\Users\username\AppData\Local\Dbg\EngineExtensions;C:\Program Files (x86)\Windows Kits\10\Debuggers\x64;C:\WINDOWS\system32;C:\WINDOWS;C:\WINDOWS\System32\Wbem;C:\WINDOWS\System32\WindowsPowerShell\v1.0\;C:\Program Files\PuTTY\;C:\Program Files (x86)\Bitvise SSH Client;C:\Program Files\nodejs\;C:\Program Files\Microsoft SQL Server\130\Tools\Binn\;C:\Program Files\Git\cmd;C:\Users\username\AppData\Local\Android\sdk\platform-tools;C:\Program Files (x86)\Nox\bin\;C:\Users\username\AppData\Local\Microsoft\WindowsApps;C:\Users\username\AppData\Roaming\npm;C:\Program Files (x86)\Nmap;C:\Program Files (x86)\mitmproxy\bin
Extension DLL chain:
C:\Windows\Microsoft.NET\Framework64\v2.0.50727\sos: image 2.0.50727.8794, API 1.0.0, built Tue Jun 20 23:15:41 2017
[path: C:\Windows\Microsoft.NET\Framework64\v2.0.50727\SOS.dll]
C:\Windows\Microsoft.NET\Framework64\v2.0.50727\SOS.dll: image 2.0.50727.8794, API 1.0.0, built Tue Jun 20 23:15:41 2017
[path: C:\Windows\Microsoft.NET\Framework64\v2.0.50727\SOS.dll]
dbghelp: image 10.0.15063.468, API 10.0.6, built Thu Jan 1 03:00:00 1970
[path: C:\Program Files (x86)\Windows Kits\10\Debuggers\x64\dbghelp.dll]
ext: image 10.0.15063.468, API 1.0.0, built Thu Jan 1 03:00:00 1970
[path: C:\Program Files (x86)\Windows Kits\10\Debuggers\x64\winext\ext.dll]
exts: image 10.0.15063.468, API 1.0.0, built Thu Jan 1 03:00:00 1970
[path: C:\Program Files (x86)\Windows Kits\10\Debuggers\x64\WINXP\exts.dll]
uext: image 10.0.15063.468, API 1.0.0, built Thu Jan 1 03:00:00 1970
[path: C:\Program Files (x86)\Windows Kits\10\Debuggers\x64\winext\uext.dll]
ntsdexts: image 10.0.15063.468, API 1.0.0, built Thu Jan 1 03:00:00 1970
[path: C:\Program Files (x86)\Windows Kits\10\Debuggers\x64\WINXP\ntsdexts.dll]

然后我将调试符号路径设置为 .pdb 所在的文件夹和 sources 文件夹。

但是当我打开源文件并在源代码行上设置断点,然后继续这个过程时,我在 windbg 中遇到错误:

0:009> g
Unable to insert breakpoint 3 at 00000000`008f001a, Win32 error 0n998
"Invalid access to memory."
bp3 at 00000000`008f001a failed
WaitForEvent failed

我预计它会中断,并向我展示 .net 汇编指令,但它一直失败。那么,如何使用 windbg 对 .net 应用程序进行断点?

最佳答案

您不能在 .NET 中使用 F9 在源文件上设置断点。相反,您需要 SOS !bpmdSOSEX !mbp 命令。

SOS语法是

!BPMD <module name> <method name>
!BPMD -md <MethodDesc>

并且它不能使用行号。

SOSEX 语法是

!sosex.mbp <source file> <line number> [<column number>] [Options]

如果 PDB 可用,可以使用行号。

!mbc 清除托管断点。 !mbd 禁用托管断点,!mbl 列出托管断点。

如果我没记错的话,有一个区别:!bpmd 仅在方法已经过 JIT 编译时才有效,因此可以在可执行机器代码中设置断点。 !mbp 可以设置断点,尽管该方法不是 JIT 编译的。一旦方法被编译,它就会自己设置断点。

关于c# - 使用 windbg 调试 .net 应用程序,无法插入断点,我们在Stack Overflow上找到一个类似的问题: https://stackoverflow.com/questions/46262536/

26 4 0